Philips HeartStart Onsite HS-1 Defribrillator

Model M5066A


Philips HeartStart Onsite HS-1 Defribrillator

Model M5066A Dimensions:
2.8"H x 7.4"D x 8.3"W

Includes: Defibrillator, battery, 1 adult SMART Pads cartridge, owners manual, quick reference guide & quick start poster (case is separate)
Waveform: Truncated Exponential Biphasic. Waveforms parameters adjusted as a function of each patient's impedence
Single Energy Output: Adult: nominal 150 Joules into a 50 ohm load
Infant/Child: nominal 50 Joules into a 50 ohm load
Automatically set based on type of SMART Pads cartridge installed
Shock to Shock Cycle Time: Typically less than 20 seconds between shocks in a series
Quick Shock: Able to deliver a shock after the end of a CPR interval, typically on 8 seconds
Voice Instructions: Detailed voice messages guide responder through use of unit
Shock Delivery: Via adhesive pads placed on patients bare skin as illustrated on pads
Controls: Green SMART Pads cartridge handle, green on/off button, blue i-button, orange shock button
Indicators: Ready light; blue i-button; caution light
Size: 2.8"Hx7.4"Dx8.3"W
Weight: With battery & pads case 3.3lbs; without battery or pads case 2.4lbs
Sealing: Solid objects per EN60529 class IP2X
Drip-proof per EN60529 class IPXI Temperature Rating: Operating 32F-122F; standby 50F-109F
Humidity Rating: Operating 0-95% relative, non-condensing; standby 0-75% relative, non-condensing
Altitude: Operating 0-15,000 feet; standby 0-8,500 feet(48hrs) & 8,500-15,000 feet (48hrs)
Shock/Drop: Can withstand 1 meter drop to any edge, corner or surface
Vibration: Meets EN1789 random & swept sine, road ambulance specification in operating & standby states
EMI Radiated/Immunity: Meets EN55011 Group I Level B Class B & EN61000-4-3
Patient Analysis: Unit will evaluate patient ECG to determine if a rhythm is shockable
Sensitivity/Specificity: Meets AAMI DF80 guidelines & AHA recommendations for adult defibrillation (Circulation 1997;95:1677-1682)
Artifact Detection: The effects of pacemaker artifact & electrical noise are minimized with artifact detection
Battery: 9 volt DC, 4.2Ah, composed of disposable long-life lithium manganese dioxide primary cells
Capacity: Minimum 200 shocks or 4 hours of operating time (EN60601-2-4:2003)
Install By Date: Battery is labeled with an install by date of at least 5 years from date of manufacture
Standby Life: 4 years typical when battery is installed by the install by date (will power the AED in standby state within the specified standby temperature range, assuming one battery insertion test & no defibrillation uses)
Warranty: 5 year
   

Click here to print a Model M5066A Sell Sheet



Accesories

SM5070A Battery
CM5072A Infant/Child SMART Pads cartridge
SM5071A Adult SMART Pads cartridge
OPT CO1 Standard carrying case
OPT CO2 Slim carrying case
YC Plastic waterproof carrying case
M3858A Defibrillator wall sign

 