Includes: Defibrillator, battery, 1 adult SMART Pads cartridge, owners manual, quick reference
guide & quick start poster (case is separate) |
| • |
Waveform: Truncated Exponential Biphasic. Waveforms parameters adjusted as a function of each
patient's impedence |
| • |
Single Energy Output: Adult: nominal 150 Joules into a 50 ohm load |
| • |
Infant/Child: nominal 50 Joules into a 50 ohm load |
| • |
Automatically set based on type of SMART Pads cartridge installed |
| • |
Shock to Shock Cycle Time: Typically less than 20 seconds between shocks in a series |
| • |
Quick Shock: Able to deliver a shock after the end of a CPR interval, typically on 8 seconds |
| • |
Voice Instructions: Detailed voice messages guide responder through use of unit |
| • |
Shock Delivery: Via adhesive pads placed on patients bare skin as illustrated on pads |
| • |
Controls: Green SMART Pads cartridge handle, green on/off button, blue i-button,
orange shock button |
| • |
Indicators: Ready light; blue i-button; caution light |
| • |
Size: 2.8"Hx7.4"Dx8.3"W |
| • |
Weight: With battery & pads case 3.3lbs; without battery or pads case 2.4lbs |
| • |
Sealing: Solid objects per EN60529 class IP2X |
| • |
Drip-proof per EN60529 class IPXI
Temperature Rating: Operating 32F-122F; standby 50F-109F |
| • |
Humidity Rating: Operating 0-95% relative, non-condensing; standby 0-75% relative,
non-condensing |
| • |
Altitude: Operating 0-15,000 feet; standby 0-8,500 feet(48hrs) & 8,500-15,000 feet (48hrs) |
| • |
Shock/Drop: Can withstand 1 meter drop to any edge, corner or surface |
| • |
Vibration: Meets EN1789 random & swept sine, road ambulance specification in operating &
standby states |
| • |
EMI Radiated/Immunity: Meets EN55011 Group I Level B Class B & EN61000-4-3 |
| • |
Patient Analysis: Unit will evaluate patient ECG to determine if a rhythm is shockable |
| • |
Sensitivity/Specificity: Meets AAMI DF80 guidelines & AHA recommendations for adult
defibrillation (Circulation 1997;95:1677-1682) |
| • |
Artifact Detection: The effects of pacemaker artifact & electrical noise are minimized
with artifact detection |
| • |
Battery: 9 volt DC, 4.2Ah, composed of disposable long-life lithium manganese dioxide primary cells |
| • |
Capacity: Minimum 200 shocks or 4 hours of operating time (EN60601-2-4:2003) |
| • |
Install By Date: Battery is labeled with an install by date of at least 5 years from
date of manufacture |
| • |
Standby Life: 4 years typical when battery is installed by the install by date (will power the AED
in standby state within the specified standby temperature range, assuming one battery insertion test
& no defibrillation uses) |
| • |
Warranty: 5 year |
| |
|
| • |