Technical
Specifications
Common
Model Specifications
All
Specifications Based on Current Production Model
2100 Series covers ADA, Elevator and Security Phones
2300 Series covers Courtesy and Handset Phones
2400 Series covers Security Speaker Phones and line powered units
| • |
Field
Programmable |
| • |
Automatic
Dialer with 31 Digit Programmable Memory |
| • |
Touch
Tone operation only. (Touch Tone is an AT&T registered
trademark.) |
| • |
Temperature
Range -40F to +150F |
| • |
Analog telephone line required-works on POTS, PBX and
central office phone lines. If used on a digital system, you
must purchase an ATA (analog telephone adaptor) from the
digital provider. They must program it with a standard wink
or disconnect signal per FCC and CRTC requirements.
|
| • |
Off
hook telephone line voltage: 48V-24V.
Most standard telephone company lines are 48V.
Many switchboard/PBX lines are 24V. |
| • |
Audible
Ring - Option on courtesy phones |
| • |
FCC
Part 68 Registered |
2100
Series-ADA, Elevator and Security Unit Specifications
| • |
ADA
Compliant (Meets all requirements of ADA, ASME A.17 and B44
Codes) |
| • |
Fully
Automated Operation |
| • |
Automatic
Answer Feature |
| • |
AC
or DC powered |
| • |
Separate
120VAC feed not required.
May tap into existing 120VAC source in elevator car operating
panel |
| • |
Remote
or On-site Programming |
| • |
Battery
Backup |
| • |
Self
Diagnostics |
| • |
Standard
five number capability |
| • |
Location Identification Message |
| • |
48V
telephone line off-hook voltage: 3.55V |
| • |
24V telephone line off-hook voltage: 3.59V
|
| • |
Loop
current 48V telephone line: 23.89MA |
| • |
Loop
current 24V telephone line: 24.32MA |
| • |
Ringer
equivalent number (REN): 0.5B |
| • |
Built-in
Consolidator feature, reach individual phone on the same telephone
line, Maximum
10 ADA SmartPhone V units per telephone line. |
2300
Series-Courtesy and Handset Phone Specifications
| • |
Telephone
line powered |
| • |
Non-volatile,
EEPROM memory |
| • |
Maximum
of three 2300 Series Handset phones per telephone line |
| • |
Optional
two-button, two number capability available |
| • |
48V
telephone line off-hook voltage: 6.43V |
| • |
24V
telephone line off-hook voltage: 6.36V |
| • |
Loop
current 48V telephone line: 23.78MA |
| • |
Loop
current 24V telephone line: 24.0MA |
| • |
Ringer
equivalent number (REN): 1.2B |
2400
Series-Security Speakerphones and Line Powered Unit Specifications
| • |
Telephone
line powered |
| • |
Non-volatile,
EEPROM memory |
| • |
Maximum
of three 2400 Series Speaker phones per telephone line |
| • |
Optional
two-button, two number capability available |
| • |
LED
specifications: 2VDC, 1/3 Watt |
| • |
Automatic
Answer Feature |
| • |
48V
telephone line off-hook voltage: 8.27V |
| • |
24V
telephone line off-hook voltage: 8.25V |
| • |
Loop
current 48V telephone line: 23.76MA |
| • |
Loop
current 24V telephone line: 23.83MA |
| • |
Ringer
equivalent number (REN): 1.1B |