IP Command Center Base Station & Distribution Module

IP Command Center Base Station & Distribution Module

In-Building Rescue Coordination designed for Elevator Installations between 1 - 128 Elevator Phones

System includes: Base Stations & Distribution Modules (Power Supply with battery backup sold separately)
Available in 3 mounting options (surface, flush and desk)

IP Command Center Surface or Flush Mount Cabinet
Surface or Flush Mount Cabinet
IP Command Center Desk Mount
Desk Mount
IP Command Center Distribution Modules
Distribution Modules


Part Numbers & Dimensions:
  • Surface Mount Cabinet:
    • Zone: 10 (2500-10RCV) 16 (-16RCV) 32 (-32RCV) 48 (-48RCV) 64 (-64XRCV) 80 (-80XRCV) 96 (-96XRCV) 112 (-112XRCV) 128 (-128XRCV)
    • Dimensions:
      • 2500-10RCV, 16RCV = 15.14" H x 12" W x 6.19" D
      • 2500-32RCV, 48RCV, 64XRCV, 80XRCV, 96XRCV, 112XRCV, 128XRCV = 21.03" H x 20.3" W x 5.19" D
  • Flush Mount Cabinet:
    • Zone: 10 (2500-10RCFV) 16 (-16RCFV) 32 (-32RCFV) 48 (-48RCFV) 64 (-64XRCFV) 80 (-80XRCFV) 96 (-96XRCFV) 112 (-116XRCFV) 128 (-128XRCFV)
    • Dimensions:
      • 2500-10RCFV, 16RCFV
        • Front Frame: 16.06" H x 14" W x 3.07" D
        • Back Box: 15.64" H x 12" W x 3" D
      • 2500-32RCFV, 48RCFV, 64XRCFV, 80XRCFV, 96XRCFV, 112XRCFV, 128XRCFV
        • Front Frame: 21.13" H x 25" W x 3.06" D
        • Back Box: 20.66" H x 23" W x 3" D
  • Desk Mount:
    • Zone: 10 (2500-10NCV) 16 (-16NCV) 32 (-32NCV) 48 (-48NCV) 64 (-64XNCV) 80 (-80XNCV) 96 (-96XNCV) 112 (-112XNCV) 128 (-128XNCV)
  • Distribution Modules:
    • Dimensions:
      • 10-48 Zone System = 2.04" H x 17.28" W x 11.8" D
      • 64-128 Zone System = 6.83" H x 17.18" W x 8.9" D

Code Compliance:
  • ADA, ASME A17, and B44 code compliant

Power Requirements:
  • Command Center is powered from the Distribution Module (IP based units require PoE)

Wiring Requirements:
  • Command Center to Distribution Module: Single pair or via IP (contact RATH® for a quote on the IP version)
  • Command Center to Distribution Module: Single pair or via IP (contact RATH® for a quote on the IP version)
  • SmartPhones to Distribution Module: Ethernet
  • Maximum 300’ run to Network Switch

Phone Capabilities:
  • Calls wait in queue until previous call is disconnected and receive a message stating that an emergency call is in progress. When the prior call clears, the next phone in queue is connected.
  • Includes handset and speaker phone for communication to phones
  • Works with 2100 series SmartPhones
  • LEDs indicate which phones have initiated a call
  • Rescue personnel can communicate with individual phones and outside party
  • Audible alert sounds when phones place a call until Command Center joins conversation

Distribution Module Features:
  • Included with Command Center
  • Surface mount
  • Install on a wall or table top
  • Requires 120vac power with battery backup or RATH® Power Supply with battery backup
  • Single dedicated phone line or as an Intercom System

Additional Features:
  • Surface or Flush Cabinets feature powder coated steel enclosure with twist lock closure
  • Works with In Car Analog Phones with Remote IP Interface or In Car IP Phones
  • Can be configured with the main Command Center, Multiple Sub-Master Stations (available in desk, surface, or flush mount) and Machine Room phones (2300-630RC)
  • In Car Analog Phone and 2300-630RC require a 2100-VOIP2CS Interface. The In Car IP Phones are a direct Ethernet connection
  • Connect 2100-VOIP2CS and In Car IP Phone to Distribution Module via an Ethernet connection. Maximum 300’ run to Network Switch.
  • System requires an analog telephone line and an IP phone line when used with the RATH® 2100-VOIP2CS Interface Device, or can be set up as an IP Intercom System

Specifications:
  • Mounting: Surface, flush, or desk mount
  • Warranty: 2 years

Downloads:


IP Command Center Base Station & Distribution Module